View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0006316 | OXID eShop (all versions) | 2.1. Master Settings | public | 2016-01-20 15:37 | 2024-03-06 09:42 |
Reporter | marco_steinhaeuser | Assigned To | |||
Priority | normal | Severity | minor | Reproducibility | always |
Status | closed | Resolution | no change required | ||
Platform | CE | ||||
Product Version | 4.9.6 / 5.2.6 | ||||
Summary | 0006316: CE shouldn't send email to OLC if option "establish a connection to the OXID servers" is not active. | ||||
Description | 0005984 not completely fixed If cURL is not available for some reason and the online license check can't be proceeded properly, an email is sent from the shop owner to olc@. See #ESDEV-2267 core/oxonlineserveremailbuilder.php core/oxonlinecaller.php In CE, it is possible to turn off the functionality "establish a connection to the OXID servers". If this option is turned off, no email should be send either. | ||||
Additional Information | http://forum.oxid-esales.com/showthread.php?t=25122 | ||||
Tags | No tags attached. | ||||
Theme | Not defined | ||||
Browser | Not defined | ||||
PHP Version | Not defined | ||||
Database Version | Not defined | ||||
related to | 0005984 | resolved | marco_steinhaeuser | email to olc@ bounces, CE editions shouldn't send E-mails to olc@ |
related to | 0006336 | resolved | SvenBrunk | Shop contacts OXID servers although "Enable connection with the OXID servers" is off |
|
All versions of OXID should contact the OLC service. There is only one exception to this rule: If there is a separate agreement between the client and OXID that this is not required. In all other instances, this checkbox only controls if the customer wants to see warnings about non-up-to-date versions. |